Note 26 PV command (pattern specified volume)
aaList of parameters set that value every time key on. When last parameter is reached, loops to the first one and it can be used when you want make strong and weak hihat with some frequency. The range is 0-127 and equivalent to V command.Note, the range of PSG tracks is 0-127 as well.(1/8 of the value is set to volume register). It is disables if 0 is set for the first parameter or V/v command is executed. If 0 is defined after parameter 0, pan pot is not set at that timing. Values are determined when it is compiled and if you use repeatings, it might not played as you want. It is not effected inside and out side of driver macros vice versa, specify for each ones.  [sample] PV120,100,90,80 cccccccc ;Same as "V120 c V100 c v90 c v80 c v120 c v100 c v90 c v80 c"  [sample] PV120,100,90,80 [cc] cc ;Not same as "V120 c V100 c v90 c v80 c v120 c v100 c", ;but as "[ v120 c v100 c ] v90 c v80 c"